MNS-BB Software User Guide
-22-
User can also set the frequency for synchronization of time from SNTP Server.
Syntax: sync [hour=<0-24>] [min=<0-59>]
Once the IP address of SNTP assigned then enable the SNTP service.
LE2425A(sntp)## sntp enable|
SNTP is enabled.
Note: If you do not have SNTP Server on your local network then you can use any public SNTP/NTP
Server. Here are a few known public SNTP/NTP Servers.
worf.ijs.si - 193.2.4.2
time.ijs.si - 193.2.4.6
time.nrc.ca - 132.246.168.164
ntp0.usno.navy.mil - 192.5.41.40
5.7.2 Time Zone
The number of minutes your time zone location is to the West (+) or East (-) of Coordinated
Universal Time (formerly GMT). The default 0 means no time zone is configured.
5.7.3 Zone and Daylight Time Rule.
These commands:
• Set the time zone you want to use
• Define the daylight time rule for keeping the correct time when
daylight-saving-time shifts occur.
Syntax: set timezone GMT=[+ or -] hour=<0-14> min=<0-59>
set timeformat format=<12|24>
set daylight country=< country name>
Note: For more details please read Appendix A.
5.8 CLI: Configuration commands
The LE2425A and LEV2525A have the following CLI commands available for configuration
management.
• Saveconf
• Loadconf
• Kill config (Hidden Command)
Note: These commands are available in ‘Manager’ privilege only.
5.8.1 To save the configuration
You can save the configuration as a binary file on the local console or FTP or TFTP Server using the
‘saveconf’ command
Syntax: saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]
LE2425A# saveconf mode=serial file=LEconfig
Note: File name is a user defined name.
5.8.2 To load or restore the configuration
You can load the configuration from the location you have saved the configuration e.g., the local
console, FTP or TFTP Server using ‘loadconf’ command.
Syntax: loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<Name>]
LE2425A# loadconf mode=serial file=LEconfig