15.5.2 Comparator
With the help of software functions Comparator 1 and 2, various comparisons of ac-
tual values with percentage-adjustable fixed values can be done.
The actual values to be compared can be selected from the following table with the
parameters Op. Mode Comparator 1 540 and Op. Mode Comparator 2 543.
If an expansion module is connected, further operation modes are available.
Operation mode 540, 543
Function
0 - Off Comparator is switched off.
1 - Absolute current
R.m.s Current
211
>
Rated Current
371
.
2 - Abs. Active Current
Active current
214
>
Rated current
371
.
3 - Abs. Stator Frequency
Stator frequency 210 > Maximum frequen-
cy 419.
4 - Abs. Actual Speed 1
Speed Sensor 2 Speed 220 > maximum speed
(calculated from Maximum Frequency 419 and
No. of Pole Pairs 373).
5 - Abs. Actual Repetition Freq.
Repetition frequency input 252 >Maximum
frequency 419.
6 -
Winding Temp.,
Temp. Follow-Up.
Winding temperature 226 > tempera-
ture 100 °C
7 - Abs. Actual Frequency
Actual frequency 241 > Maximum frequen-
cy
419.
9 - DC –Link Voltage
DC Link Voltage
222 > Direct voltage 1000 V.
10 -
Abs. Isq
Isq
216 >
Rated Current
371.
11 -
Abs Filtered Active Current
Active current
214 >
Rated current
371.
12 - Abs. Internal Ref. Frequency
Internal Reference Frequency 228 >Maximum
Frequency
419.
13 - Abs. Ref. Percentage Value
Reference Percentage Value 229 > Maximum
Reference Percentage
519.
14 -
Abs. Actual Percentage Val-
ue
Actual Percentage Value 230 > Maximum
Reference Percentage
519.
15 - Abs. Analog Input MFI1A
Analog Input MFI1A
251 > input signal 100 %
100 to 107, 111, 112
Operation modes with signs (+/-).
The switch-on and switch-off thresholds for compactors 1 and 2 are set by the para-
meters Comparator on above 541, 544 and Comparator off below 542, 545.
The percentage limits of the corresponding reference values are indicated.
Parameter
Settings
No.
Description
Min.
Max.
Fact. sett.
541
Comparator 1 On above
- 300.00 %
300.00 %
100.00 %
542
Comparator 1 Off below
- 300.00 %
300.00 %
50.00 %
544
Comparator 2 On above
- 300.00 %
300.00 %
100.00 %
545
Comparator 2 Off below
- 300.00 %
300.00 %
50.00 %
204 Operating Instructions ACU 06/13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 401-23 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 401-23 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 401-23
CategoryInverter
LanguageEnglish

Related product manuals