6.5. FUSE SELECTION
Blown fuses typically indicate a semiconductor device failure or a severe transient. In
any case, blown fuses should not be replaced without first consulting Bonitron as
catastrophic damage can occur. Use Tables 6-6 and 6-7 when initially constructing
the system.
Note: AC fuses must be J-type or equivalent.
Table 6-6: Fuse Current Rating Requirements
MODEL
NUMBER
AC / DC FUSE
CURRENT RATING
M3645-x030
40A
M3645-x050
60A
M3645-x100
125A
M3645-x300
350A
Table 6-7: Fuse Voltage Rating Requirements
SYSTEM
VOLTAGE
AC FUSE
VOLTAGE RATING
DC FUSE
VOLTAGE RATING
230240VAC
240 VAC
350 VDC
380480VAC
600 VAC
700 VDC
575600VAC
600 VAC
1000 VDC