NOTICE!
Risk of material damage due to incorrect handling of
mechanical seals!
Make sure not to damage the sealing surfaces of the new
seal faces.
— The sealing surfaces must be clean and should not be
scratched.
12. If delivered separately
, fit the O-rings (5) onto the new seal
faces (4). The mechanical seals are normally equipped with
O-rings on delivery.
NOTICE!
Risk of loss of seal function due to oil/grease on the O-
rings of mechanical seals!
Material damage resulting from loss of seal function
— The O-rings of a mechanical seal must be installed
without oil or grease.
NOTE!
Spray cleaner (degreaser)
Generally, the seal faces equipped with O-rings can be
inserted dry
.
— In order to ensure that they are free of grease and to aid
insertion, the O-rings can be sprayed lightly, depending
on their resistance, with a quickly-volatilizing spray
cleaner (degreaser) that leaves no residue.
13. Remove the handle from the Multitool (M).
Maintenance and Repairs