Introduction

Due to normal wear and tear, these units require regular maintenance to ensure safe operation
and optimum performance. The above chart provides a schedule of the minimum recommended
maintenance tasks.
 

After (SEE TABLE) of refrigerant has been
filtered. Refer to “Filter Change” in the
Maintenance section of this manual.
Model
R134a
Replacement lter at:
68 kg (alert 56 kg)
Model
R1234yf
Replacement lter at:
150 kg (alert 138 kg)

When the lter is replaced or every 100 hours.
Refer to “Vacuum Pump Maintenance” in the
Maintenance section of this manual.


Monthly.

Monthly. Refer to “Calibration Check” in the
Maintenance section of this manual. Every year
all scales must be calibrated by an authorized
service center.

Whenever it is necessary. Refer to “Scales Reset”
in the Maintenance section of this manual.

Automatic every 10 days. Refer to “Pressure
Decay Leak Test” in the Maintenance section
of this manual (for R1234yf only).
Every yearly — performed by an authorized
service center (for R134a only).
 Monthly.
 Monthly. Use a clean cloth.
 Monthly. Use a clean cloth.


Daily.


Monthly.

Every yearly — performed by an authorized
service center.


Daily.



Every six months or whenever it is dirty and / or
clogged. Replace the sample hose assembly
during every lter change. Refer to “Refrigerant
Identier Maintenance” in the Maintenance
section of this manual.

Table of Contents