SoftwareDescription
FlexibleAutomation
5−17
Bit 15 07891011121314
S10
XXXXXXXX
Bytenumber
X:arbitrary
MarkerRange
M0
M100
M101
M255
.
.
.
.
.
.
.
.
Non−remanentRange
RemanentRange
EntryinS10:K101D
Fig.5−12Marker RemanencyS10
Time RemanencyS12 Limiting (byte) address for timer remanency
Default Byte 0−7 non−remanent (T0−T63)
Byte 8−15 remanent (T64−T127)
Example
;Definition of the timer remanency limit
L W K4H,B ;T32 = 1st remanent timer
T W B,S12
Bit15 21034567891011121314
S12
XXXXXXXXXXXX
X:arbitrary
Bytenumber
Fig.5−13Time RemanencyS12