EasyManua.ls Logo

Bosch CL3000iU W 26 E - Technical Data and Specifications; Indoor Unit Technical Data; Outdoor Unit Technical Data; General Unit Specifications

Bosch CL3000iU W 26 E
248 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tech data
57
Climate 3000i – 6721823680 (2023/03)
8Tech data
Table 73
Indoor Unit CL3000iU W 26 E CL3000iU W 35 E CL3000iU W 53 E CL3000iU W 70 E
Outdoor Unit CL3000i 26 E CL3000i 35 E CL3000i 53 E CL3000i 70 E
Cooling
Rated output kW
kBTU/h
2.6
9
3.5
12
5.3
18
7.0
24
Power input at rated output W 733 1096 1550 2402
Output (min. - max.) kW 1.0-3.2 1.4-4.3 2.1-5.9 3.4-8.2
Power input (min. - max.) W 80-1100 120-1650 420-2050 560-3200
Cooling load (Pdesignc) kW 2.8 3.6 5.3 7.0
Energy efficiency (SEER) 7.4 7.0 7.0 6.4
Energy efficiency class A++ A++ A++ A++
General information – on heating
Rated output kW
kBTU/h
2.9
10
3.8
13
5.6
19
7.3
25
Power input at rated output W 771 1027 1750 2130
Output (min. - max.) kW 0.8-3.4 1.1-4.4 1.6-5.8 3.1-8.2
Power input (min. - max.) W 70-990 110-1480 300-2000 780-3100
Heating – with colder climate
Heating load (Pdesignh) kW 3.8 3.8 6.7 10.8
Energy efficiency (SCOP) 3.1 3.4 3.1 2.7
Energy efficiency class B A B D
Heating – with average climate
Heating load (Pdesignh) kW 2.5 2.5 4.2 4.9
Energy efficiency (SCOP) 4.1 4.2 4.0 4.0
Energy efficiency class A+ A+ A+ A+
Heating – with warmer climate
Heating load (Pdesignh) kW 2.5 2.5 4.5 5.3
Energy efficiency (SCOP) 5.2 5.5 5.1 5.1
Energy efficiency class A+++ A+++ A+++ A+++
General
Power infeed V / Hz 220-240 / 50 220-240 / 50 220-240 / 50 220-240 / 50
Max. power consumption W 2150 2150 2500 3700
Max. current consumption A 10 10 13 19
Refrigerant – R32 R32 R32 R32
Refrigerant charge g 600 650 1100 1450
Design pressure MPa 4.3/1.7 4.3/1.7 4.3/1.7 4.3/1.7
Indoor Unit
Ex-protected ceramic fuse on main board T 3.15 A/250 V T 3.15 A/250 V T 3.15 A/250 V T 3.15 A/250 V
Volumetric flow rate (high/medium/low) m
3
/h 520/460/330 530/400/350 800/600/500 1090/770/610
Sound pressure level (high/medium/low/
noise reduction)
dB(A) 37/32/22/20 37/32/22/21 41/37/31/20 46/37/34.5/21
Sound power level dB(A) 54 56 56 62
Permissible ambient temperature
(cooling/heating)
°C 17...32/0...30 17...32/0...30 17...32/0...30 17...32/0...30
Net weight kg 8.0 8.7 11.2 13.6
Outdoor Unit
Ex-protected ceramic fuse on main board – T 20 A/250 V T 20 A/250 V T 30 A/250 V T 30 A/250 V
Flow rate m
3
/h 1850 1850 2100 3700
Sound pressure level dB(A) 56 55 57 60
Sound power level dB(A) 62 63 65 67
Permissible ambient temperature
(cooling/heating)
°C –15...50/–15...24 –15...50/–15...24 –15...50/–15...24 –15...50/–15...24
Net weight kg 23.5 23.7 33.5 43.9

Table of Contents

Related product manuals