Page 120 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART V: REFRENCE MATERIALS
59.5 Miscellaneous Issues
Problem Cause Solution
There are numbers in braces
{###} throughout this
document.
These numbers {###} refer to the event
numbers
Control Panel Events and
Reporting
Formats on page 124.
N/A
My printer is printing strange
characters and I cannot read it.
The settings for the DX4010i/DX4010 RS-
232 Serial Interface Module can cause
unexpected printer output.
Verify the settings for the following parameters (see
the
DS7200V2 Expert Programming Guide
P/N: 4998153891):
DX4010 Output Configuration (Address 1253)
Baud Rate Configuration (Address 1254)
Parity/Flow Control/Stop Bit Configuration (Address
1255)
Network communication is not
working as expected.
The DX4020 Network Interface Module
is not properly wired and/or configured.
The control panel is not properly
programmed for network
communication
Make sure the DX4020 is properly connected to
the control panel. See
DX4020 Wiring on page
30.
Make sure the DX4020’s DIP switches are set to
Address 134 (see
DX4020 Addressing on page
28).
Make sure your selection for Address 3541
includes the “Alternate Communication Interface
at Address 134” option. See
Network Interface
Module Options
on page 115.
See the DX4020 Installation Guide (P/N: 49522)
for additional configuration requirements.
Make sure you are using a valid IP address and
that you entered it correctly. See
IP Address 1 (2)
for Destination 1 (2)
on page 112.
Make sure selection for Alternate Communication
Options
(see page 113) includes the “Enable
Alternate Communication” option.
60.0 Data Bus Address Quick Reference
Data Bus Address Device Description
0 Installer Keypad or local connection to RPS
1-8 Keypads/DACMs 1-8
40, 41 DX8010 Telephone Control Module
50 Premises RF Receiver 1
51 Premises RF Receiver 2
52-55 Premises RF Keypads Receiver 1
60-63 Premises RF Keypads Receiver 2
101-107 DX2010 Wired Input Expanders
134 DX4020 Network Interface Module (NIM)
150, 151 DX3010 Output Expanders
250 DX4010i/DX4010 Serial RS-232 Interface Module
Table 44: Data Bus Address Quick Reference