Page 68 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
40.0 Help Function Keys and Duress Parameters
The parameters in this section configure the keypad’s Help Function keys and the Duress function for all keypads and areas.
Each key has 16 characters of programmable text that is displayed when the key is activated as follows.
To activate the function assigned to the Help Function Keys, press and hold (1 second at least) the following keypad
combinations:
[1]+[3] keys
[4]+[6] keys
[7]+[9] keys
Area Options for Help Function Keys
Address:
[1]+[3] Keys: 0694
[4]+[6] Keys: 0696
[7]+[9] Keys: 0698
Default:
DS7240V2: 15
DS7220V2: 3
Selections: 0-15
Enter This Data Digit to Select Options
Keypad Help Function Keys Area Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
Disabled for all Areas
Keys work for Area 1
Keys work for Area 2
Keys work for Area 3 (DS7240V2 only)
Keys work for Area 4 (DS7240V2 only)
Use this parameter to assign areas to the keypad Help Function Keys. The keys report as follows:
[1]+[3] keys reports as Zone 100 for all Areas
[4]+[6] keys reports as Zone 101 for all Areas
[7]+[9] keys reports as Zone 102 for all Areas