DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 69
PART IV: CONTROL PANEL PROGRAMMING
Alarm Response for Help Function Keys
Address:
Alarm Response for [1]+[3] Keys: 0695
Alarm Response for [4]+[6] Keys: 0697
Alarm Response for [7]+[9] Keys: 0699
Default: 0 (No Alarm Response)
Selections:
0 = No Alarm Response
1 = Activate Fire Alarm Response
2 = Activate Panic Alarm Response
3 = Activate Emergency Alarm Response
This parameter determines the alarm response for the Help Function keys.
Fire Alarm Response: If enabled, this option displays “Fire Alarm Key #” at the text keypads. If programmed, the control
panel sends a Fire Alarm {75} report and activates the Fire Alarm output.
Panic Alarm Response: If enabled, this option displays nothing and no sounds are emitted at the keypads. If programmed,
a Panic {6} report is sent and the Burglary Alarm output is activated.
Emergency Alarm Response: If enabled, this option displays “Alarm Key #” at the text keypads. If programmed, an
Emergency Alarm {4} report is sent and the Burglary Alarm output is activated.
The following letters are assigned to the Help Function keys and appear in the alarm response
message that is displayed by the text keypad:
[1]+[3] = A
[4]+[6] = B
[7]+[9] = C
For example, if Fire Alarm Response is assigned to keys [1]+[3], then “Fire Alarm Key A” appears. If
Emergency Alarm Response is assigned to keys [1]+[3], then “Alarm Key A” appears.
Alarm Output Option for Help Function Keys
Address: 0700
Default: 0
Selections: 0-7
Enter This Data Digit to Select Options
Alarm Output Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
No Alarm Output for Keypad Help Function Keys
Alarm Output for [1]+[3] Keys
Alarm Output for [4]+[6] Keys
Alarm Output for [7]+[9] Keys
Reserved
Use this parameter to assign an alarm output option to the Help Function keys. The alarm output activates for the response
type assigned to each key sequence. This is a global parameter that affects all areas.

Table of Contents