Page 70 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
Keypad Help Function Keys Text
Address:
[1]+[3]: 1298-1329
[4]+[6]: 1330-1361
[7]+[9]: 1362-1393
Default:
[1]+[3]: Keypad Panic
[4]+[6]: Keypad Fire
[7]+[9]: Keypad Emergency
Selections: See Table 21 on page 40
Enter up to 16 characters to describe the Keypad Help Function key sequences.
Duress Reporting Options
Address: 0702
Default: 1
Selections: 0-15
Enter This Data Digit to Select Options
Duress Reporting Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
No User Emergency Function Reporting
Make User 32 a Duress User
Make User 31 a Duress User
Make User 30 a Duress User
Make User 29 a Duress User
This parameter creates up to 4 Duress users (and PINs). Creating a Duress user does not change any other function
programmed for that user.
Whenever a user enters a Duress PIN (PIN assigned to a Duress user), the control panel sends a Duress {74} report and
executes functions per the Duress user’s authority level.
DS7240V2 Procedure
To create a unique Duress user (and PIN) for each area, select Option 15 and then assign each of the four users (User 29
through 32) to only one area.
To create one Duress user (and PIN) for all areas, select Option 1, 2, 4 or 8 and then assign that user (User 29 through 32) to
all four areas.
DS7220V2 Procedure
To create a unique Duress user (an PIN) for each area, select Option 3, 5, 6, 9, 10, or 12, and then assign the two
corresponding users (User 29 through 32) to only one area.
To create one Duress user (and PIN) for both areas, select Option 1, 2, 4, or 8, and then assign that user (User 29 through 32)
to both areas.