Page 56 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
Open/Close Reporting Options
Address: 0261
Default: 0
Selections: 0-15
Enter This Data Digit to Select Options
Open/Close Reporting Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
No Open, Close, Exit Error, or Recent Close Reports
Opening {89-96, 164} Reports Enabled
Closing {42-67, 165} Reports Enabled
Exit Error {18} Report Enabled
Recent Closing {19-20} Reports Enabled
This is a global parameter that affects all zones, all areas, and all PINs.
Opening and Closing reports can be restricted by area (see Area # Opening {89-96}/Closing {42-67}
Reporting Options on page 61) and by authority level once they are enabled and configured here.
Reporting must be enabled at the system level first (see Global Reporting Options on page 47).
Opening Reports Enabled: If selected, this option enables Opening {89 to 96, 164} reports.
Closing Reports Enabled: If selected, this option enables Closing {42 to 67, 165} reports.
Exit Error: Only the Exit Error {18} report is enabled and disabled by this option. If an Entry/Exit Delay zone (Zone Function
Types 11 and 12) is violated at the end of Exit Delay, these events occur in this order:
1. Local alarm annunciation is started (keypads and alarm outputs).
2. Entry Delay starts.
3. The alarm report process begins if the system is not turned off at the end of Entry Delay. An Exit Error {18} report is
included if programmed. The Exit Error report follows the Alarm Report routing.
Recent Closing: If this option is enabled, an Alarm Recent Closing {19 to 20} report (including the user number) is sent for
any alarm within 2 minutes of the end of Exit Time.
Opening/Closing Report Routing
Address: 0262
Default: 1 (Reports to Destination 1, Events to Log/Printer)
Selections:
0 = No Reports, no Events to Log/Printer
1 = Reports to Destination 1, Events to Log/Printer
2 = Reports to Destination 2, Events to Log/Printer
3 = Reports to Destinations 1 & 2, Events to Log/Printer
4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5 = No reports, Events to Log/Printer
This is a global parameter that affects all zones, all areas and all PINs.
The Exit Error {1} and Recent Closing {19-20} reports follow alarm routing. See
Communication Attempt Tables on page 121
for communication attempt sequences, and
Communication Failure (Comm Fail) on page 13 for a description of a Comm Fail
event.
You must enable reporting at the Global Reporting Options prompt (see page 47) and enter at least one
phone number (or IP address) for one routing destination (see page 42).