DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 87
PART IV: CONTROL PANEL PROGRAMMING
Area, Output #
• Address: See Table 31
• Default:
− Outputs 1-4, 11-20: 1 (Assign Output to Area 1)
− Outputs 5-10: 0 (No Area Assigned – Output disabled)
• Selections: 0-15
Enter This Data Digit to Select Options
Output Area Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
No Area Assigned (Output disabled)
•
Assign Output to Area 1
•
•
•
•
•
•
•
•
Assign Output to Area 2
•
•
•
•
•
•
•
•
Assign Output to Area 3 (DS7240V2 only)
•
•
•
•
•
•
•
•
Assign Output to Area 4 (DS7240V2 only)
•
•
•
•
•
•
•
•
This parameter assigns an area to the output. Functions are only activated by keypads or zones assigned to the same area.
Outputs can be assigned to multiple areas.