Bosch HPC 400 - Calling Up Information About the System; Heating;Cooling; DHW; Pool

Bosch HPC 400
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BOSCH
6.3
Heating/cooling
settings
I
System
data
Priority
heating
eireu~
1
1-
--
Heating
eire
. 1
Heating
eire
. 2
Heating
eire.
3
> I
Service
menu
6.3.1
System
data
Settings
for
the
entire
system
can
be
made
in
this
menu.
For
example
.
the
value
for
the
minimum
outside
temperature
or
the
thermal
storage
capacity
of
the
building
can
be
set
here.
Additional
settings
for
heating!
cooling
circuit
1
are
available
in
this
menu
(if
directly
connected
to
the
heat
source).
6720
811
136-502.
20
Fig
. 6
Set
heating/cooling
menu
Config.
HCl
at
appliance
D
I
Min
.
outdoor
temperature
Damping
Type
of
building
No
own
heating
circuit
pump
Via
pump
PC1
-35
...
-10
...
10
°C
No
Heavy
I
Medium
Light
No
Yes
Yes
r
rost
sensor
coolin
-g
--
-----
-
--
-
~
Table
24
Settings
in
the
system
data
menu
1)
Valid
only
for
exhaust
air
heat
pumps
.
Minimum
outside
temperature
Hydraulic
and
electrical
connection
of
heating/cooling
circuit
1
to
device
.
I
The
internal
pump
of
the
heat
source
is
also
used
as
the
pump
in
heating/cooling
circuit
1.
A
buffer
cylinder
I
is
not
required.
Heating/cooling
circuit
1
is
not
directly
connected
to
the
heat
source
.
In
this
case
. a
buffer
cylinder
is
not
installed
(see
previous
menu
item).
Pump
PCl
in
heating/cooling
circuit
1
is
electrically
connected
to
the
heat
source
.
There
is
a
bypass
between
heating/cooling
circuit
1
and
the
heat
pump
for
the
purposes
of
hydraulic
separation.
1-
With
weather-compensated
control
the
minimum
outside
temperature
affects
the
heating
curve
(7
Minimum
outside
temperature
.
page
17
and
Menu
for
setting
of
the
heating
curve
.
page
20)
.
The
set
building
type
affects
the
measurement
of
the
outside
temperature
.
The
outside
temperature
is
delayed
(dampened).
The
measured
outside
temperature
is
included
unadjusted
in
the
weather-compensated
control.
Measure
of
the
thermal
storage
capacity
of
the
heated
building
(7
Type
of
building
.
page
17).
High
storage
capacity
.
significant
damping
of
the
outside
temperature.
e.g.
brick
building
Medium
storage
capacity
.
~edium
damping
of
the
outside
temperature.
e.g.
hollow
concrete
blocks
Low
storage
capacity.
low
damping
of
the
outside
temperature.
e.g.
prefabricated
building.
wood-frame
-'
construction
Frost
sensor
for
cooling
installed
.
No
frost
sensor
for
cooling
installed.
The
minimum
outside
temperature
is
the
average
value
of
each
of
the
coldest
outside
temperatures
or
recent
years.
and
it
has
an
influence
on
the
heating
curve
.
The
value
for
the
region
can
be
taken
from
the
required
heat
load
calculation
that
should
be
done
for
every
building
or
from
the
climate
zone
chart
or
from
Tab
.
25
.
~
Set
the
minimum
outside
design
temperature
for
the
heating
system
.
London
- 1
Rome
- 1
Budapest
Madrid
- 4
Sevastopol
-12
Bucharest
Marseilles
- 6
Stockholm
-19
Hamburg
-12
Moscow
-
30
Valencia
- 1 I
Helsinki
-
24
Naples
- 2
Vienna
-15
Istanbul
- 4
Nice
± 0
Zurich
-16
Table
25
Minimum
outside
temperatures
for
Europe
Type
of
building
If
damping
is
activated.
the
adjustment
of
the
outside
temperature
fluctuations
can
be
set
with
the
building
type.
By
adjusting
the
outside
temperature
thermal
inertia
of
the
building
mass
is
taken
i
nto
account.
Thus.
by
setting
the
building
type
the
control
can
be
adapted
to
suit
the
characteristics
of
the
building.
aOc
+-
________
-.
__________
~
ah
12 h
24
h
6720 645 480-30.
10
Fig
. 7
Example
for
adjusted
outside
temperature:
[1]
current
outside
temperature
[2]
adjusted
outside
temperature
This
greatly
simplified
example
shows
how
the
adjusted
outside
temperature
follows
the
current
outside
temperature.
but
does
not
reach
its
extreme
values.
HPC
400 -
fi
720821
-72
(201
11
0/
1
17