Bosch HPC 400 - Function Test Menu

Bosch HPC 400
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BOSCH
The
Diagnos
is
service
menu
contains
a
number
of
tools
for
diagnosis
.
Note
that
the
menu
items
shown
will
vary
depending
on
the
heating
system.
6.1
0
.1
F
unct
i
on
test
men
u
This
menu
can
be
used
to
test
active
heating
system
components
individually.
If
Enable
function
tests
is
set
to
Yes
in
this
menu,
the
normal
heating
mode
is
interrupted
in
the
entire
system.
All
settings
are
saved
.
The
settings
in
this
menu
are
only
temporary
and
revert
to
the
respective
default
settings
as
soon
as
Enable
function
tests
is
set
to
No
or
the
Function
test
menu
is
closed.
The
available
functions
and
the
possible
settings
vary
depending
on
the
system
installed.
A
function
test
is
performed
by
setting
the
setting
values
of
the
listed
component
accordingly
.
You
can
check
whether
the
compressor,
mixing
device,
pump
or
valve
responds
appropriately
by
inspecting
the
behaviour
of
the
corresponding
component.
For
example,
the
DHW
circulation
pump
can
be
tested
as
follows:
Off
:
The
pump
stops.
On
:
The
pump
starts.
6.
10
.2
Mon
i
tored
values
menu
This
menu
contains
the
heat
system
settings
and
measured
values.
E.g.
the
flow
temperature
or
current
DHW
temperature
is
displayed
.
Here,
you
can
also
find
detailed
information
about
system
units,
e.g.
the
indoor
unit
temperature.
The
information
and
values
that
are
provided
depend
on
the
system
that
has
been
installed.
The
technical
information
of
accessory
modules
and
other
system
units
must
be
observed.
6.
10.3
Fault
display
menu
The
current
faults
and
the
fault
history
can
be
called
up
in
this
menu.
present
in
the
system
are
displayed
here
.
System
error
history
The
last
20
faults
for
the
entire
system
are
displayed
here
,
sorted
in
order
of
the
time
of
occurrence.
The
fault
history
can
be
deleted
in
the
Reset
menu
(~ChapterS.lO.S,
page
27)
.
Heat
appliance
error
history
The
last
20
faults
for
the
heat
pump
are
displayed
here,
sorted
in
order
of
the
time
of
occurrence
.
For
each
faultthat
is
stored
, a
I
snapshot
is
available
of
the
data
recorded
in
the
system
at
the
time
the
fault
occurred
(~
Snapshot
function,
page
27)
.
The
fault
history
can
be
deleted
in
the
Reset
menu
(~
Chapter
S.
10
.
S,
page
_2_
7)
=-
.
__
Table
35
Information
in
the
fault
display
menu
Snapshot
function
To
obtain
additional
information
that
will
help
you
with
troUbleshooting
if a
fault
occurs:
~
Open
the
following
menus
:
Servi
ce
men
u >
Diagnosis
>
Fault
display
s>
Heat
applia
nce
error
history
.
~
Turn
the
selector
until
the
fault
you
are
searching
for
appears.
~
Press
and
hold
the
info
key
until
a list
containing
the
data
recorded
at
the
time
the
selected
fault
occurred
is
displayed.
~
Turn
the
selector
to
view
additional
data
in
the
list.
6.
10
.4
System
in
formatio
n
me
nu
The
software
versions
of
installed
BUS
units
in
the
system
are
displayed
in
this
menu
.
6.
10
.5
Maintenance
sett
i
ng
s
The
contact
details
for
the
company
that
is
to
perform
the
maintenance
can
be
stored
in
the
Ma
i
ntenance
menu
.
These
details
are
also
displayed
in
the
event
of
a
fault.
Service
menu
6.1
0
.6
Reset
menu
You
can
delete
settings
or
lists
or
reset
them
to
the
default
setting
in
this
menu
.
I
Heat
pump
fault
history
The
fault
history
is
deleted.
If
currently
a
fault
is
present.
the
fault
history
is
recorded
agai
~
The
heat
pump
fault
history
is
deleted.
If
currently
a
fault
is
present,
the
fault
history
is
I
recorded
again
.
Service
messages
Heating
circuits
time
prog
The
service
messages
are
reset.
- -
---
The
time
programs
of
all
heating
circuits
are
Time
prog
.
DHW
f--
Solar
thermal
system
Hours
run
Default
setting
I
reset
to
the
default
setting.
. . I
All
time
programs
of
the
DHW
system
(mcludmg
the
time
program
for
the
DHW
circulation
pump)
are
reset
to
the
default
setting
. I
1
All
settings
referring
to
the
solar
system
are
reSet1
to
the
default
setting
. I
I
The
solar
system
must
be
recommissioned
after
I
I
this
reset!
I
The
hours
run
meterforthe
heat
pump
is
resetto
I
zero
.
All
settings
are
reset
to
the
corresponding
default
setting
.
The
system
must
be
recommissioned
after
this
reset!
Table
36
Resetting
settings
6.
10
.7
Calibrat
i
on
menu
~
Place
a
suitable
precision
measuring
instrument
close
to
the
user
interface.
The
I
precision
measuring
instrument
may
not
give
off
any
heat
to
the
user
interface.
I
~
Keep
heat
sources
such
as,
e.g.
direct
sun,
body
heat
and
the
like
away
for
a
period
of
1
hour.
~
Adjust
the
displayed
room
temperature
correction
value
( - 3
..
. 0
...
+ 3
K).
Time
correction
This
correction
( -
20
- 0
...
+
20
s)
is
performed
automatically
once
every
week.
Example:
the
clock
is
offset
by
ca.
-6
minutes
per
year
·
-6
minutes
per
year
-360
seconds
per
ye
J r
·1
year
=
52
weeks
·-360
seconds:
52
weeks
·-6.92
seconds
per
week
·
Correction
factor
= + 7
s/week
.
---
---
Table
37
Calibration
menu
settings

Other manuals for Bosch HPC 400