EasyManua.ls Logo

Bosch HPC 400 - DHW Settings

Bosch HPC 400
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service
menu
@
BOSCH
Menu
item
Adjustment
range
d
es
cr
iption
Screed
dry
. H.
ci
rc
. 1
..
.
Yes
Screed
dry
i
ng
in
the
selected
heating
ci
rcuit
is
act
i
ve/not
active
Screed
dry
. H.
circ
. 4
No
Start
I
Yes
Start
screed
drying
now
I
No
Screed
drying
not
yet
started
or
terminated
----
Interrupt
!
Yes
Temporar
i
ly
stop
screed
drying
.
If
the
max
i
mum
interruption
duration
has
been
exceeded
, a
fault
display
is
No
output.
-::-
----
--
Cont
i
nue
Yes
Continue
screed
dry
i
ng
after
stop.
I
No
Table
30
Setting
in
the
Screed
drying
menu
(Fig
. 13
shows
the
default
setting
of
the
screed
drying
program)
30
~~-
~-+
-+-+~-
20 <-=t----r----r--+--+-+---r-+__
o 1 2 3 4 5 6 7 8 9 10
11
12 13 14 15 16 17 18 19 20
21
22
6720 815 238
-1
8.10
Fig
. 13
Screed
drying
process
with
default
settings
t
Time
6.4
DHW
settings
~
i~
IIHW
')('lTlfll~S
!
DH
W system
i On
DHW
>
DH
W reduced
>
DH
W circulation p
ump
i
on
II
start frequen
cy
DHW eirc.
i 3/h
6 720
811
136-503.
20
Fig.
14
DHW
settings
menu
The
settings
for
the
DHW
system
can
be
adapted
in
this
menu
_
For
example
,
here
you
can
set
the
DHW
temperature
ranges
for
the
various
operating
modes
or
whether
there
is
circulation
in
the
DHW
system.
The
day
and
time
for
thermal
disinfection
are
also
set
here
.
DHW
heat
pump
1
(DHW
heat
pump
2)
Off
On
TCxFlow
temperature
of
heating
circuit x
(identical
to
system
flow
tem
-
perature
TO
if
only
one
heating
circuit
is
installed)
[]
The
DHW
system
is
activated
by
default
when
delivered
.
If
no
DHW
system
is
installed,
but
one
is
activated
,
the
user
interface
indicates
a
fault.
~
If
no
DHW
system
is
installed
in
the
system
,
deactivate
DHW
system
I
in
the
Commissioning
or
DHWmenu
.
11
WARNING:
Risk
of
scalding!
I
The
DHW
temperature
can
be
set
above
60°C
and
,
during
thermal
disinfection
,
the
DHW
is
heated
to
above
60
°C.
~
Inform
all
people
concerned
and
make
sure
that a
mixing
device
is
i
nstalled
.
DHW
e.g.
15
...
60·C
...
65
·C
ON
temperature
and
OFF
temperature
for
the
DHW
operating
mode
;
the
adjustment
range
depends
on
the
installed
heat
source
.
DHWreduced
e.
g.
15
.
..
45
...
60
·C
ON
temperature
and
OFF
temperature
for
the
DHW
reduced
operating
mode
;
the
adjustment
range
depends
on
the
i
nstalled
heat
source
.
DHW
circulation
pump
On
I
If
the
OHW
circulation
pump
is
to
be
controlled
by
the
heat
source
,
the
DHW
circulation
pump
must
be
activated
here
as
well.
The
default
sett
i
ng
depends
on
the
i
nstalled
heat
source
.
I-
Off
The
DHW
circulation
pump
cannot
be
controlled
by
the
heat
source
.
Table
31
Settings
in
the
DHW
menu
24
HPC
1\00
- 6 720821772 (2017/07)

Other manuals for Bosch HPC 400