Service
menu
6.3.2
Priority
heating
circuit
1
BOSCH
In
the
default setting
any
changes
in
the
outside
temperature
have
an
effect after a
delay
of
three
hours
at
the
latest
on
the
calculation
of
the
weather-
compensated
control.
~
To
view
the
course
of
the
outside
temperature
of
the
last
2
days;
open
the
Info
>
Room
and
outdoor
temp.
>
Outdoor
temp.
curve
menu
This
menu
item
allows
the
other
heating
circuits
to
be
restricted
via
heating
circuit L If a
heat
requirement
comes
from
heating
circuit 1
and
others
simultaneously.
this setting
is
used
to
determine
whether
the
heat
requirement
forthe other
heating
circuits
is
always
met
Depending
on
the
setting.
the
heat
requirement
forthe other
heating
circuits
is
only
met
if
heating
circuit 1
is
supplied
accordingly_
Priority
heating
circuit
1
No
Heating
circuit
1
is
the
primary
heating
circuit.
Heat
requirements
for
other
circuits
are
only
handled
if
heating
circuit
1
1
has
a
heat
requirement.
The
flow
temperature
required
for
heating
circuit
1
limits
the
flow
temperature
of
the
other
heating
circuits
_
Example
:
HK1
requires
50
'C
.
HK2
requires
55
"C.
but
receives
a
maximum
of
50'C
(in
line
with
HK1)
.
HK3
requires
45'C
and
receives
45'C
(notlimited
by
HK1)
.
Unmixed
heating
circuit
1
will
be
forced
to
run
when
any
other
circuit
requests
heat.
So
heating
circuit
1
might
have
a
higher
temperature
then
wanted
.
Table
26
Settings
in
the
Priority
heating
circuit
1
menu
6.3.3
Settings
for
heating
circuit
1 ... 4
Settings
for
the
individual
heating/cooling
circuits
can
be
made
in
this
menu.
For
example
.
you
can
set
which
heating
system
is
installed
for
the
selected
heating/cooling circuit.
In
addition
it
can
be
set
whether
a
remote
control
is
available
and
which
control
type
is
used.
It
is
also
possible
to
optimise
the
heating
curves
of
the
heating/cooling circuits.
NonCE:
Risk
of
damaging
the
screed!
~
If
an
underfloor
heating
system
is
used.
the
max
. flow
temperature
recommended
by
the
manufacturer
of
the
system
should
be
observed.
At
the
module
User
interface
CR10H
A
heating/cooling
circuit
is
not
installed.
If
no
heating/cooling
circuit
is
installed.
the
heat
source
is
only
used
for
DHW
heating
.
Electrical
assemblies
and
components
of
the
selected
heating/cooling
circuit
are
directly
connected
to
the
I
heat
source
(only
available
with
heating
circuit
1)
.
Electrical
assemblies
and
components
of
the
selected
heating/cooling
circuit
are
connected
to
an
MM
100
module.
CR
10
is
installed
as
a
remote
control
for
the
heating/cooling
circuit.
This
allows
compensated
control
influenced
by
room
temperature
.
=-:--::-----,:------:--1
CR
10
is
installed
as
a
remote
control
for
the
selected
heating/cooling
circuit.
This
allows
for
weather
-
compensated
control
influenced
by
room
temperature.
~------------~------~------~----~--~----~---
ext.
room
temp
.
sensor
Yes
An
additional
room
temperature
sensor
is
installed
(no
CR
10lCR
10
H)
.
This
allows
for
weather
-
No
----II
Heating
system
heat
circ.
1
Radiator
I i
Convector
heater
Circuit
function
I
Ctrl
type
h.
clrc.
1
l
__
r
Max
.
flow
temperature
Set
heating
curve
I
Underfioor
Heating
I
Cooling
Heating
and
cooling
0
Outdoor
temp.
compensated
Outside
temp
.
with
low
end
30 ... 75
..
. 85'C
(radiator/convector)
30
...
48
...
60'C
(underfloor
heating
system)
compensated
control
influenced
by
the
room
temperature
.
No
additional
room
temperature
sensor
is
installed
.
-----
----
Factory
default
of
the
heating
curve
according
to
heating
type
,
e.g
.
curvature
and
design
temperature
The
selected
heating/cooling
circuit
is
only
used
to
provide
heating
in
the
corresponding
room
.
The
selected
heating/cooling
circuit
is
only
used
to
provide
cooling
in
the
corresponding
room
.
--
--
The
selected
heating/cooling
circuit
is
only
used
to
provide
heating
and
cooling
in
the
corresponding
room
.
Further
information
on
the
control
type
for
the
selected
heating
CIrCUit
(
~
Control
types
for
the
heating
system,
page
20)
Maximum
flow
temperature
I
Fine
adjustment
of
the
heating
curve
that
is
preset
via
the
heating
system
(~
Set
the
heating
system
and
heating
curve
for
weather-compensated
control,
page
20)
----~~--~----------~
Table
27
Settings
in
menu
heating/cooling
circuit
1 .
..
4

Other manuals for Bosch HPC 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch HPC 400 and is the answer not in the manual?

Bosch HPC 400 Specifications

General IconGeneral
BrandBosch
ModelHPC 400
CategoryControl Panel
LanguageEnglish

Related product manuals