MAP 5000 Initial set-up and programming | en 63
Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332
Reportable external tamper
alarm
Reporting of external tamper alarm event, possibly also
delayed if present/absent option is used
Reportable panel summary
trouble
Reporting of panel summary trouble event, possibly also
delayed if present/absent option is used
Reportable panel summary
armed
Reporting of panel summary armed
Reportable external fire alarm Reporting of duress alarm event, possibly also delayed if
present/absent option is used
Anti-mask intrusion trouble Covering of a motion detector
External tamper alarm disarmed Tamper alarm from disarmed area with simultaneous
reporting via the communicator
Transmission path fault In the event of communication failure between
communicator and receiver
Ethernet path layer1 fault In the event of failure of connection to network connector
Wireless path layer1 fault In the event of failure of connection to network
– field strength insufficient
– registration not possible
– GPRS service not available
– no connection to the DE module
IPC reporting failure No acknowledgment received from the receiver within 240
sec.
4.6.2 Sirens and communicator in accordance with EN50131 grade 3
Notice!
Sirens must be in operation for at least 90 seconds and a maximum of 15 minutes, unless
local or national requirements demand a shorter duration.
The following variants are possible:
Variant A (ICP-MAP0007 DE module and ICP-COM-IF required)
– Two supervised sirens
Connections 10 / 11 and 12 / 13 on the ICP-MAP0007 DE module)
– One communicator (class 4)
Connections R1 – R7 on ICP-COM-IF
Variant B (ICP-COM-IF required)
– One self-powered siren
Outputs 10 / 11 or 13 / 14 on ICP-MAP5000 main panel
– One communicator class 4
Outputs R1 – R7 on ICP-COM-IF
Variant C (ICP-COM-IF required)
– One communicator class 4 (main communicator)
Outputs R1 – R7 on ICP-COM-IF
– One communicator class 3 (additional communicator)
Outputs R1 – R7 on ICP-COM-IF or other outputs on panel