10 en | Introduction MAP 5000
2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH
Wire diameter Wire cross-
section
Length A Length B Length C Length D
0.8 mm 0.503 mm
2
. 325 m - - - - - - - - -
0.8 mm 0.503 mm
2
. 100 m 135 m - - - - - -
0.8 mm 0.503 mm
2
. 50 m 225 m - - - - - -
0.8 mm 0.503 mm
2
. 50 m 50 m 50 m - - -
1.0 mm 0.785 mm
2
. 500 m - - - - - - - - -
1.0 mm 0.785 mm
2
. 175 m 175 m - - - - - -
1.0 mm 0.785 mm
2
. 100 m 325 m - - - - - -
1.0 mm 0.785 mm
2
. 100 m 75 m 75 m - - -
1.0 mm 0.785 mm
2
. 50 m 400 m - - - - - -
1.0 mm 0.785 mm
2
. 50 m 125 m 125 m - - -
1.0 mm 0.785 mm
2
. 50 m 50 m 50 m 50 m
Tab.1.1: Cable lengths
The following applies for VdS
For remote operation of the IPP-MAP0005 power supply, a control center assigned to the
same area must be provided for indication of power supply trouble (trouble in mains supply /
battery).
1.5.2 Planning the system with ICP-MAP0012 CAN splitter module
4 When using a CAN splitter module to split the external BDB into two independent areas,
chose one of the following wiring possibilities:
Wiring with a CAN splitter module and a MAP LSN gateway module