MAP 5000 Installation | en 19
Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332
Mounting an edge protection profile
Element Description
1 cut-outs
2 edge protection profile
2.4 Checking the AC connection
1. Ensure that the AC circuit breaker switch is off.
2. Connect the AC line to the AC terminal block.
3. Switch the AC breaker on.
4. Verify that the circuit breaker does not trip and that appropriate line voltage is present on
the fused side of the AC terminal block.
5. Switch the AC breaker off and continue with the rest of the installation.
Warning!
After ensuring the AC connection is functional, turn the AC breaker off before continuing the
installation process.
2.5 Installing the power supply and AC terminal block
Caution!
Debris
Damage to the power supply due to debris during the installation is possible.
– To prevent damage to the power supply during installation, ensure that the supplied
protective dust cover label is on top of the power supply before installing it.
1. Slide the left side of the power supply against the flange on the left side of the enclosure
back wall.
2. Align the cut-out on the right side of the power supply.
3. Secure the power supply to the enclosure back wall with the supplied hardware in the
following order: external tooth washer, washer, hex nut