76 en | Appendices MAP 5000
2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH
2. Include a control center if not yet present.
3. Include the area in the scope of the control center: Local Area.
4. Program control center for arming with exit delay: Use Area Normal Delay Time.
5. The value for the entry / exit delay can be adapted if required: Area Manager > Area >
Timing and Delays:
normal entry delay (typically 45 sec. / at least 30 sec.)
normal exit delay (typically 60 sec.)
Programming entry / exit route
1. Program all points of the entry / exit route to the point type intrusion.
2. Select the type of exit point optionally for exit route points:
Exit point type Behavior
Initial follower
1
Point without prevention of arming readiness, e.g. PIR that has the
control center in the detection area. Important: point must be in
normal state after exit, otherwise an alarm will be tripped
Follower
1
Point that does not trip an alarm as long as the exit delay is
running. Only relevant for option MAP5000 Panel > Armed State At
Exit Delay Start
Exit Door point that must be mandatorily tripped once upon leaving the
area. The option MAP5000 Panel > Unvacated Premises must be
activated
Interrupt Door point that shortens the running exit delay to 10 sec.
(recommended)
Restart Point that restarts the exit delay; possible only once during the exit
Tab.8.4: Exit point types
1)
Not for EN 50131
4 Select the type of entry point for all entry route points.
Entry Point Type Behavior
Delay 'Normal' Door point that starts the entry delay with the value 'Normal'
Delay 'Extended' Door point that starts the entry delay with the value 'Extended'
Follower Point that does not trip an alarm as long as the entry delay is
running
Tab.8.5: Entry Point Types
Programming delayed reporting for all intrusion points of the area
1. For all points of the point type Intrusion and Intrusion 24h, set the parameter Supports
Delayed Reporting to Yes.
2. For reporting (Event Manager > Panel Event Groups > Properties > Reportable Events),
set a Transmission Delay that is the same as the exit delay (typically 45 sec. / at least 30
sec.) for External Intrusion Alarm.