4 Technical data
4.1 Operating behavior
4.1.1 Description of the specified parameters
Maximum energy content
E
max
= energy content at speed n
max
. Unit [kJ].
Rated power
P
N
= nominal power of the storage device at rated speed n
N
. Unit [kW].
Continuous power
P
C
= continuous power output depending on the DC bus voltage. Unit [kW].
Maximum power
P
max
= maximum power output depending on the DC bus voltage. Unit [kW].
Rated current
I
N
= phase current of the energy storage device at rated speed for reaching
the rated power, specified as rms value in ampere [A].
Maximum current
I
max
= maximum briefly allowed phase current that has no damaging effect on
the winding, specified as rms value in ampere [A].
Rated speed
n
N
= working speed defined by the manufacturer. Depending on the applica‐
tion, other speeds are possible (see characteristic curve).
Maximum speed
n
max
= maximum allowed speed of the storage device. The maximum speed
can be limited by mechanical factors, such as centrifugal forces or bearing
wear. Unit [min
-1
]
Thermal time constant
T
th
= thermal time constant for Rexroth temperature model. For further notes
on the temperature model, refer to the Rexroth IndraDrive MPx application
manual
Discharge capacity
C
ab
= capacitance of short-circuited power connections U, V, W against the
housing. Unit: [nF].
Number of pole pairs
p = number of pole pairs of the storage device.
Power wire cross-section A
Unit: [mm²]. Rated for cables by current carrying capacity according to VDE
0298-4 and laying type B2 according to EN 60204-1 at a surrounding air tem‐
perature of 40 °C. Other installation methods or higher ambient temperatures
may require a higher power wire cross-section.
Mass
m = mass of the energy storage device. Unit [kg].
Moment of inertia of the rotor
J
rot
= moment of inertia of the rotor without bearing and encoder. Unit: [kgm²].
Sound pressure level
L
P
= at a distance of 1 m, with PWM = 4 kHz. Unit: [dB(A)].
Energy content for n
Range_P
N
E
n_P
N
= the specified energy content of the storage device in the specified
speed range. Unit [kJ].
Speed range for energy content
E
n
P
N
n
Range_P
N
= speed range in which the storage device can be charged and dis‐
charged with constant rated power.
Energy content for n
Range_P
max
E
n_P
max
= the specified energy content of the storage device in the specified
speed range. Unit kilojoule [kJ].
Speed range for energy content
E
n
P
max
n
Range_P
max
= speed range in which the storage device can be charged and dis‐
charged with constant maximum power.
Permissible coolant inlet tempera‐
ture
Please also observe the information provided under Coolant temperature set‐
ting.
Maximum allowed coolant input
pressure
Please also observe the information in chapter8.6.3 .