2. Tighten knurled nut "securely", in doing so, retrace cable.
3. Check the firm seat of the connection by short pull on the connector.
4. Secure the cables, that accruing forces due to cable vibrations onto the
connector are prevented.
8.4 SpeedCon connectors
Damage to persons or property by discon‐
necting or connecting energized connectors!
WARNING
Connect and disconnect connectors only when they are dry and de-
energized.
During operation of the system, all connectors must be securely tight‐
ened or locked.
Observe when connecting the flange sockets:
Protect the flange sockets from external force effect.
Connect the energy storage device to ready-made connection cables.
Connect SpeedCon connectors
Properly measured ready-made connection cables are available. Plug con‐
nector type, size, wire cross section
1. Insert power connector in position “open”.
2. "Manually" tighten the power connector with a rotation by approx. 90°.
3. Check the firm seat of the SpeedCon quick lock by short pull on the con‐
nector.
4. Secure the cables, that accruing forces due to cable vibrations onto the
connector are prevented.
30/73
Connection technique
BA1N Kinetic Energy Buffer
Bosch Rexroth AG R911393264_Edition 01