10.4.3 Storage instructions
Storage conditions
Generally, Bosch Rexroth recommends storing all components until they are
actually installed in the machine as follows:
● in their original packaging
● at a dry and dust-free location
● at room temperature
● free from vibrations and oscillations
● protected against light or direct sunlight
Upon delivery, protective sleeves and covers can be attached to the
BA1N energy storage device. They have to remain on the BA1N energy stor‐
age device for transport and storage. Do not remove these parts until shortly
before assembly.
Based on DIN EN 60721-3-1, the tables below specify classifications and lim‐
it values which are allowed for our products while they are stored. Refer to
the detailed description of the classifications to take all of the factors which
are specified in the particular classification into account.
Allowed classes of ambient conditions during storage acc. to DIN EN
60721-3-1
Classification type Class
Classification of climatic ambient conditions 1K2
Classification of biological ambient conditions 1B1
Classification of chemically active materials 1C2
Classification of mechanically active materials 1S1
Classification of mechanical ambient conditions 1M2
Tab. 10-3: Allowed classes of ambient conditions during storage
For a better overview, some essential environmental influencing variables of
the previously mentioned classifications are listed. Unless otherwise speci‐
fied, the specified values are the values of the particular class. However,
Bosch Rexroth reserves the right to adjust these values at any time based on
future experiences or changed environmental factors.
Environmental condition classes allowed for storage according to DIN EN
60721-3-1
Environmental factor Symbol Unit Value
Air temperature
T
L
°C
-20 ... +60
1)
Relative air humidity φ % 5 … 95
Absolute air humidity ρw g/m³ 1 ... 29
Condensation - - - - Not permitted
Ice formation/freezing - - - - Not permitted
Direct solar radiation - - - -
Not allowed
1)
Occurrence of salt mist - - - -
Not permitted
1)
1) Differs from DIN EN 60721-3-1
Tab. 10-4: Allowed storage conditions
BA1N Kinetic Energy Buffer 51/73
Handling and transport
R911393264_Edition 01 Bosch Rexroth AG