Parameter
1)
Symbol Unit
BA1N16-C3BHA
(forced ventilation)
BA1N16-C3BHL
(water cooling)
Energy content for n
P
max
E
n
P
max
kJ 122.7 69.8
Speed range for energy content E
n
P
max
n
Range_P
max
min
-1
2450 ... 6000 2300 ... 4730
No-load losses
2)
at 4000 min
-1
P
V_4000
kW 3.82 4.10
1) Observe the notes in chapter 4.1.1 .
2) In order to increase energy efficiency, it is recommended to on‐
ly reduce the magnetizing current to 10 % after a cycle break
time of 2 s. In doing so, there is an anticipated reduction in no-
load losses of approx. 60 % at a no-load speed of 4000 rpm.
3) Tolerance ± 5%
4) Rated current limited by connection plug (power)
Tab. 4-1: Technical data BA1N16
4.2.2 Forced ventilation – BA1N16 fan data
Parameter Symbol Unit Value
Voltage type - - 3~ AC
Air flow direction - - blowing
Medium volume current -
m
3
/h
520.0
Nominal voltage
U
N
V 400 480
Nominal frequency f Hz 50 / 60 50 / 60
Fan current
1)
I
N
A 0.21 / 0.26 0.28 / 0.25
Blocking current
I
block
A 0.64 / 0.6 0.76 / 0.73
Power consumption
S
N
VA 145 / 180 233 / 208
1) Fan current monitoring should start at I
N
+ 20%.
Tab. 4-2: Data sheet BA1N16 fan
4.2.3 Water cooling – Technical data
Parameter Symbol Unit Value
Power dissipation
P
V
kW 3.7
Coolant inlet temperature
T
in
°C 10 ... 40
Permissible coolant temperature increase for P
V
ΔT
max
K 10
Pressure drop at Q
min
Δp bar 0.1
Constant for determining pressure drop
K
Δp
/ 0.01
Required coolant flow for P
V
Q
min
l/min 5.0
Coolant channel volume
V
cool
l 0.99
Maximum allowed inlet pressure
p
max
bar 6.0
Tab. 4-3: Water cooling – Technical data
BA1N Kinetic Energy Buffer 19/73
Technical data
R911393264_Edition 01 Bosch Rexroth AG