3.6 Air Gate
This feature supports air gate operation. It requires a digital input to monitor the air cylinder position.
When the input status changes the controller switch between 1
st
and 3
rd
solid and prewet materials, and
also set operation gate position to calibrated gate position for the material selected.
3.7 Gate Readback and Automatic Gate
Gate Readback Automatic Gate
It requires a gate sensor to measure It requires a gate cylinder with a
the current gate position. sensor to measure the gate position.
Sensor A2-A (Junction box) Sensor A2-A (Junction box)