6 Set Up Error Messages
Error Messages
#
Suggested Solution
01-BLAST TOO LONG
1
Blast held too long
02-LIQ BLST TOO LONG
2
Liquid blast held too long
03-OVER SPEED
3
Slow down, reset max speed
04-ERR SPN OUTPUT
4
Check cables, check coil
05-ERR CONV OUTPUT
5
Check cables, check coil
06-ERR CRS1 OUTPUT
6
Check cables, replace coil
07-ERR CRS2 OUTPUT
7
Check cables, replace coil
08-NO GRANULAR DET
8
Load material, check sensor
09-NO LIQUID DET
9
Load material, check sensor
10-NO GROUND SPEED
10
Check cable/sensor
11-NO CONV FEEDBACK
11
Check cable/sensor
12-NO WET FEEDBACK
12
Check cable/sensor
13-NO LIQ FEEDBACK
13
Check cable/sensor
Warning Messages
#
Suggested Solution
21-UNLOAD NOT ALLOWED
21
Vehicle needs to be stationary
22-SYSTEM ERROR !!!
22
Reboot, or re-flash
23-NO RC,CHK FUSE/CONNECTION
23
Comm failure between display and RC
24-LIQUID BOOM OPERATION ERROR
24
Need at least one boom to work
25-NO JOY1,CHK CONNECTION
25
Comm failure between RC and Joy 1
26-NO JOY2,CHK CONNECTION
26
Comm failure between RC and Joy 2
27-NO GATE POS SENSOR
27
Check gate sensor, cable break
28-GATE CLOSED
28
Gate closed in READBACK mode
29-NO SIMULATE
29
Speed Simulation mode stopped
30-SPN UNDER APP
30
Spinner not able to reach desired RPM
31-SOLID UNDER APP
31
Rate or spd too hi, incorrect calib
32-PREWET UNDER APP
32
Rate or spd too hi, incorrect calib
33-LIQ UNDER APP
33
Rate or spd too hi, incorrect calib
37-GND SPD CALIBRATION
37
Too few or no pulses, recalibrate
38-SPINNER CALIBRATION
38
Bad or no sensor
39-CONVEYOR CALIBRATION
39
Bad or no sensor
40-PREWET CALIBRATION
40
Too few pulses, or sensor failed
41-LIQ CALIBRATION
41
Too few pulses, or sensor failed
42-SPN CAL: WRONG CTRL MODE
42
Auto null not allowed for MAN mode
43-CNV CAL:WRONG CTRL MODE
43
Auto-null or calibration not allowed
44-PREWET CAL:WRONG CTRL MODE
44
Auto-null or calibration not allowed
45-LIQ CAL:WRONG CTRL MODE
45
Check Anti-icing or CrsCnv modes
46-CRS CNV CAL:WRONG MODE
46
Check Cross-Conv mode setting
47-CALIBRATION ERROR
47
Check sensor, recalibrate
48-CALIBRATION ERROR
48
Check sensor, recalibrate
xx-CALIBRATION ERROR
49
.
.
70
Check sensor, recalibrate

Other manuals for Bosch Rexroth CS660