The following Errors are warning messages, and not user configurable.
Error 21 Unload Not Allowed. Vehicle needs to be stationary to activate UNLOAD function.
Error 22 - System Error. This can be caused by loading a wrong parameter file or wrong firmware file. Default
and reboot, or re-flash the RC to see if it clears the error, otherwise report to Bosch Rexroth.
Error 23 - Communication failure between the RC controller and the display. Check display fuse and inspect
all CANbus connections.
Error 24 All booms are closed. Need at least one boom open to run liquid pump.
Error 25 - Joystick 1 communication failure. This will shut down the joystick outputs. Check if joystick
connection inside the armrest is loose, otherwise report to Bosch Rexroth.
Error 26 - Joystick 2 communication failure. This will shut down the joystick outputs. Check if joystick
connection inside the armrest is loose, otherwise report to Bosch Rexroth.
Error 27 - No Gate Sensor. Gate sensor failure, most likely caused by cable break. This will force the gate
control into Manual.
Error 28 - Gate Position is Zero. This will occur only if the gate position is zero while in gate Read-back and
Automatic gate modes. The conveyor will not be allowed to move until the gate is detected open.
Error 29 - No Ground Speed Simulation. This is just an information message to indicate that ground speed
simulation mode has been stopped.
Error 30 Spinner Under Application. Desired RPM can not be achieved. Check spinner min/max outputs
and recalibrate spread width.
Error 31 Solid Under Application. Desired RPM can not be achieved. Possibly caused by too high
application rate or too high ground speed or incorrect calibration.
Error 32 Prewet Under Application. Desired Pre-wet flow can not be achieved. Caused by too high
application rate or too high ground speed or incorrect calibration.
Error 33 Liquid Under Application. The anti-ice pump cannot meet the desired flow setpoint. Caused by
too high application rate or too high ground speed or incorrect calibration.
Error 37 Ground Speed Calibration. Pulses Too Low. Calculated pulses per km is too low during
calibration. Possibly caused by no sensor feedback, or try recalibrating the ground speed sensor.
Error 38 - Spinner Calibration Error. During auto nulling, the calculated maximum RPM was too low, most
likely caused by no sensor feedback.
Error 39 - Conveyor Calibration Error. During auto nulling, the calculated maximum RPM was too low, most
likely caused by no sensor feedback.
Error 40 - Pre-Wet Maximum Hz Too Low. During auto nulling, the calculated maximum Hz was too low, most
likely caused by no sensor feedback.
Error 41 Liquid Calibration Error. During auto nulling, the calculated maximum Hz was too low, most likely
caused by no sensor feedback.
Error 42 Spinner Wrong Control Mode, Auto-Null not allowed
Error 43 Conveyor Wrong Control Mode, Auto-Null not allowed