EasyManua.ls Logo

Bosch Rexroth IndraDrive CSB02 - ESD Protection; Limited Number of Plug-In Actions

Bosch Rexroth IndraDrive CSB02
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESD Protection
Risk of damage to the control section and in‐
terference
with its operational safety caused
by electrostatic charges!
NOTICE
Exposed conductive parts coming into contact with the control section must
be previously discharged by means of grounding.
Such exposed conductive parts include:
The
human body (ground connection by touching a conductive, groun‐
ded object)
Parts and tools (place them on a conductive support)
Control sections may only be stored or dispatched in conductive packaging.
Limited Number of Plug-In Actions
Risk of damage to the control section or pow‐
er section by mounting and dismounting the
control section too often!
NOTICE
For a drive controller, the control section must not be mounted and dismoun‐
ted more than a maximum of 20 times.
Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P12/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Introduction
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Table of Contents

Related product manuals