8.11 Relay Contacts
8.11.1
Relay Contact Type 2
Fig. 8-34: Relay contact
Data Unit Min. Typ. Max.
Current carrying capacity mA 10 1000
Voltage load capacity V 30
Contact resistance at minimum cur‐
rent
1000
Switching actions at max. time con‐
stant of load
1 × 10
6
Number of mechanical switching cy‐
cles
1 × 10
8
Time constant of load ms ohmic
Pick up delay ms 10
Drop out delay ms 10
Tab. 8-38: Relay Contacts Type 2
Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P126/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Technical data - functions