8.8 Analog Voltage Input
AD Analog/digital converter
Fig. 8-32: Analog Voltage Input
Data Unit Min. Typ. Max.
Allowed input voltage V -30 +30
Working range input voltage U
on_work
V -10 +10
Input resistance R
u
150 300
Input bandwidth (-3 dB) kHz 1,3
Common-mode range V -30 +30
Common-mode rejection dB 50
Relative measuring error at 90%
U
on_work
% -1 +1
Resolution Bit
14
1)
13
2)
Cables For cable lengths > 30 m, only use
shielded cables.
1) Applies to: Cxx02 control sections (X32), optional I/O extension
DA (X38), HCS01 drive controllers (X32)
2) Applies to: Control sections with extended scope CSx02.1B
(X35), CDB02.1B (X36)
Tab. 8-35: Analog Voltage Input