Installation 27/40
RE 30110-B/11.2012, VT-VSPA2-1-2X/V0/T., Bosch Rexroth AG
Table 8: Allocation of the male multipoint connector
Pin Row d Row b Row z
2 Command value call-up 1 (24V input) Command value 1
(potentiometer port connection ±10 V)
Solenoid a+
4 Command value call-up 2 (24V input) Command value 2
(potentiometer port connection ±10 V)
Solenoid a–
6 Command value call-up 3 (24V input) Command value 3
(potentiometer port connection ±10 V)
Solenoid b+
8 Command value call-up 4 (24V input) Command value 4
(potentiometer port connection ±10 V)
Solenoid b–
10 Ramp call-up 1 (24V input)
3)
Inverting of command value (24V input) Reserved
12 Ramp call-up 2 (24V-C)
3)
Ramp on/off (24V input) Reserved
14 Ramp call-up 3 (24V input)
3)
Command value 5+ (10 V) Reserved
16 Ramp call-up 4 (24V input)
3)
Command value 5– (–10 V) Reserved
18 Enable (24V input) Reserved Reserved
20 Reserved 4-quadrant operation (24V input)
3)
System earth
22 Ready for operation signal
(24V, active high, 50 mA)
Command value 6+ (4 to 20mA) Reserved
24 Ramp external Command value 6– (4 to 20mA) Reserved
26 Reserved Measuring point signal Reserved
28 Reference/ramp external Reference potential for outputs (M0) Reserved
30 Command value output ±10 V –10 V/25 mA Operating voltage (24 V)
32 Actual value output ±10 V +10 V/25 mA L0 (0 V)