EasyManua.ls Logo

Bosch WAL28PH7NL - Page 46

Bosch WAL28PH7NL
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NL Troubleshooting
Malfunction Cause and Troubleshooting
"E:36 / -10" Unauthorized extension mounted on the water drain
hose.
Remove unauthorized extensions to the wa-
discharge hose. Connect device
Pump cover is not fully screwed in.
Make sure that the pump cover is up to the stop
screwed into the device. The pump cover handle
must be vertical.
"Cleaning the drain pump", Page 44
"E:36 / -25 / -26" Drain pump is clogged.
"
Cleaning the drain pump", page 42
"E:10 / -00 / -10 /
- 20"
Pump of the intelligent dosing system is blocked.
1. Switch off the device.
2. Clean the pump unit.
"Cleaning the detergent drawer",
Page 41
3. If the indication reappears, enable the service.
"Service", page 58
Remark: You can start the washing program if you
deactivate the intelligent dosing system and dose
manually.
"Keys", Page 24
Water pressure is low.
No solution possible.
Strainer in the water supply is clogged.
Clean the strainer in the water supply.
Water tap is closed.
Open the water tap.
Water supply hose is kinked or pinched.
Make sure that the water inlet hose is not
nods or clenches.
"E:35 / -10" Water in the bottom tray.
Close the tap.
Please contact customer service.
"Service", page 58
Device is leaking.
Close the tap.
Please contact customer service.
"Service", page 58