Troubleshooting NL
Malfunction Cause and Troubleshooting
The detergent drawer is not closed as far as it will go.
▶ Push the detergent drawer into the appliance as far as it will go.
ready.
Pump unit is not installed.
1. Place the pump unit in the detergent drawer.
→
"Cleaning the detergent drawer",
Page 41
2. Push the detergent drawer into the appliance as far as it
will go.
flashes. The voltage monitoring system detects an
impermissible voltage drop.
▶ No solution possible.
Remark: When the supply voltage has stabilized, the
program continues normally.
Undervoltage can cause a program extension.
No solution possible.
Detergent dosage is too high.
▶ Immediate measure: mix a tablespoon of fabric softener
ter with 0.5 l of water and pour this mixture into
the manual dosing compartment (not for outdoor,
sportswear and down textiles).
▶ When the intelligent dosing is activated, re-
then induce the basic dosing amount
→
Page 36.
▶ When dosing manually, reduce to the full
next wash with the same load, the amount
ness detergent.
burns. Temperature is too high.
▶ Wait for the temperature to drop.
▶ → "
program cancel", Page 33
Water level is too high.
▶ Start the program Pump down .
Laundry is wedged in the door.
1. Open the door again.
2. Remove trapped laundry.
3. Close the door.
4. To start the program, press .
47