Fault finding and diagnosis
Worcester 2000 – 6 721 814 551 (2019/09)
68
1076 R No signal from heat exchanger temperature
limiter.
Check plug, connect correctly.
Check heat exchanger temperature limiter, replace if required.
Check connecting lead for breaks, replace if required.
Check and replace the appliance electronics.
2051 Internal fault. Disconnect power from the system for 30 seconds.
Check and replace control unit.
Notify customer service.
2085
2908
V
V
Internal fault in burner control unit. Reset appliance.
If the fault persists following a reset, the burner control unit is faulty and must be
replaced.
2909 System fault, appliance electronics / basic
controller
If the fault persists following a reset, the burner control unit or Key (including
interconnecting leads) is faulty and must be replaced.
2910 V Fault in flue system. Check whether a flue system is connected, install if required.
Check for unobstructed cross-section of flue system, remove deposits if required.
2911 Calibration failed. Replace faulty component.
2912 No flame signal during calibration. Replace faulty component.
2913 Flame signal too low during calibration. Check and replace flame sense electrodes (and interconnecting leads).
2914 System fault, appliance electronics. If the fault persists following a reset, the appliance control unit is faulty and must
be replaced.
2915 V System fault, appliance electronics. Reset appliance.
If the fault persists following a reset, the control unit is faulty and must be replaced.
2916 V System fault, appliance electronics. Reset appliance.
Trigger heat demand.
End heat demand.
If the fault persists, the control unit is defective and must be replaced.
2917 V No flame signal when checking the combustion
control.
Disconnect power and then reconnect.
Trigger heat demand.
Wait 5 minutes.
If the fault re-occurs within that time, reset the appliance without disconnecting
the supply voltage.
This triggers a calibration of the ionisation circuits.
If the fault is still present after the calibration, the control unit is faulty and must be
replaced.
2918 Fault in the flue. Clean the siphon and drain water out of the appliance (gas side).
2920 V Flame monitoring fault. Check electrodes and connecting leads, replace if required.
Check earthing connections.
Check appliance electronics, replace if necessary.
2921 B The appliance is in test mode ( Menu 5,
page 49).
2922 Internal burner control fault. Check and replace control unit.
2923
2924
V
V
System fault, appliance electronics. Reset appliance - factory reset.
If the fault persists following a reset, the appliance electronics are faulty and must
be replaced.
2925
2926
V
V
System fault, appliance electronics. Check the gas valve, replace if required.
Check appliance electronics, replace if necessary.
Fault
code
Fault
category
Description Remedy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester GC2000iW 30 C NG and is the answer not in the manual?

Bosch Worcester GC2000iW 30 C NG Specifications

General IconGeneral
BrandBosch
ModelWorcester GC2000iW 30 C NG
CategoryBoiler
LanguageEnglish

Related product manuals