Fault finding and diagnosis
69
Worcester 2000 – 6 721 814 551 (2019/09)
2927 B No flame detected during ignition. Check the main shut-off valve, open if necessary.
Check the appliance isolation valve, open if necessary.
Measure the gas supply pressure at the rated heat input. If necessary, shut down
the appliance and check the gas line.
Check flame sense electrode and connecting lead, replace if required.
Check venturi/injector for potential blockage.
Measure the ionisation current.
Check the protective conductor connection in the control unit.
Check the ignition cable for damage, replace if necessary.
Check functionality of gas valve and replace if necessary.
Check burner setting value at rated heat input.
Check burner setting value at the lowest output.
Check flue system.
Check combustion air supply.
Check the heat exchanger on the flue gas side for deposits, clean if necessary.
2932 Internal fault. Restart the appliance.
2928
2930
2931
2940
V
V
V
V
Internal fault in burner control unit. Reset appliance - factory reset.
If the fault persists following a reset, the burner control unit is faulty and must be
replaced.
2941 B Insufficient flow rate in heat source. Check plug of flow temperature sensor, connect correctly if required.
Check flow temperature sensor, replace if necessary.
Check pump for blockage, clear if required.
Check pump settings, correct if required.
Check water pressure, if necessary top up until the preset pressure is reached.
2942 No fan speed feedback. Connect plug for speed control to the fan.
Connect plug for power supply to the fan.
Check fan harness.
Check and replace control unit.
2943 Mains voltage too low. Establish supply voltage of at least 196 VAC.
2945 V Too many short heat demands in a short time. Reset appliance - factory reset.
Increase restart blocking time.
Make sure that at least one thermostatic valve is open.
Check and replace faulty heating pump.
Check diverter valve functionality, replace if necessary.
2946 V Incorrect code plug. Check code plug, replace if necessary.
2947 R Anti-seizing function is activated. The function stops automatically.
2948 B No flame signal with low output. The burner restarts automatically after purging.
Check CO
2
settings.
2949 B No flame signal with high output. The burner restarts automatically after purging.
Check burner gaskets, replace if required.
Check CO
2
settings.
2950 B No flame signal following starting procedure. Check CO
2
settings, adjust if necessary.
Check Burner and heat exchanger gaskets
Check gas pressure during burning at full load
Burner restarts automatically after purging
2951 V Loss of flame too frequent. Refer to the blocking error(s) that lead to this locking error. Check the fault history
on appliance.
Possible purging of gas pipe incomplete.
Could also indicate a wide variety of issues such as pipework undersized or gas
pressure dropping off, incorrectly routed condense drains, incorrectly sited flues,
incorrectly wired etc.
2952 V Internal fault when testing the ionisation signal. Restart appliance to see if problem re-occurs.
If the fault remains after resetting, the burner controller (PCB) is defective
Fault
code
Fault
category
Description Remedy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester GC2000iW 30 C NG and is the answer not in the manual?

Bosch Worcester GC2000iW 30 C NG Specifications

General IconGeneral
BrandBosch
ModelWorcester GC2000iW 30 C NG
CategoryBoiler
LanguageEnglish

Related product manuals