User manual WTS Ver.1.16
Seite 23 von 52
By confirming with the setpoints operation can be set to the value ‘0’:
-

: relay switching will not occur if the setpoint value is ‘0’.
-

:
- Setpoint = ’0’ and

=

, relay switching occurs when the weight is ‘0’; the
relay will switch again when the weight is different from zero, taking hysteresis into
account (both for positive and for negative weights).
- Setpoint = ’0’ and

=

, relay switching occurs for a weight higher than or
equal to ‘0’, the relay will switch again for values below ‘0’, taking hysteresis into
account.
- Setpoint = ’0’ and

=

, relay switching occurs for a weight lower than or
equal to ‘0’, the relay will switch again for values above ‘0’, taking hysteresis into
account.
INPUTS
Default: input 1 =

input 2 =

Possible operation modes:
-

(NET/GROSS): by closing this input for no more than one second, it’s making an
operation of SEMI-AUTOMATIC TARE and the display will show the net weight. To display
the gross weight again, hold the NET/GROSS input closed for 3 seconds.
-

: by closing the input for no more than one second, the weight is set to zero (see
paragraph SEMI-AUTOMATIC ZERO (WEIGHT ZERO-SETTING FOR SMALL
VARIATIONS)).
-

: keeping the input closed the maximum weight value reached remains on
display. Opening the input the current weight is displayed.
-

: closing the input no operation is performed, the input status may however be read
remotely by way of the communication protocol.
-

: closing the input for max one second the weight is transmitted over the serial
connection according to the fast continuous transmission protocol only once (only if

is set in the item

).
-

: when the input is closed the weight is displayed based on the set coefficient (see
setting of the units of measure and coefficient), otherwise the weight is displayed.