107
TEST PROCEDURES
13.3 Apply a 1 kHz, -19.3 dBV input to the
channel 1 and 2 RCA input jacks.
13.4 Measure the output level at the channel
1 and 2 output jacks. It should be +31 dBV
+/- 1 dBV.
13.5 Reduce the input signal level to < -55.2
dBV. Verify that after a 20 minute period that
the amplifier switches to standby mode.
13.6 Increase the input signal level above
-55.2 dBV. Verify that the amplifier comes
out of standby mode after about 2 seconds.
PROCEED TO THE HI-POT AND
GROUND BOND TESTS ON PAGE 114
------------------->