Page 34 - Programming Manual 24805480/14-11-2012 319F92C ver. 1.2 -The data and information in this manual may be changed at any time with no obligation on BRAHMS’s part to notify anyone of this.
ENGLISH
ERR.COM.KEYPAD xx
KEYPAD DESCR.
The xx keypad is no longer communicat-
ing with the control unit (read warning led
on keypad is flashing). Check activation of
keypad, bus cable and address.
X
ERR.MOD.IN xx
MODULE DESCR.
The inputs expansion module on bus xx
no longer communicates with the control
unit (the red led communication light is not
flashing). Check activation of module, bus
cable and dip switch address.
X
ERR.MOD.OUT xx
MODULE DESCR.
The outputs expansion module on bus xx
no longer communicates with the control
unit (the red led communication light is not
flashing). Check activation of module, bus
cable and dip switch address.
X
ERR.MOD.RX xx
MODULE DESCR.
The radio receiver module on bus xx no
longer communicates with the control unit
(the red led communication light is not
flashing). Check activation of module, bus
cable and dip switch address.
X
JAM.MOD.RX xx
MODULE DESCR.
The radio receiver module on bus xx has
detected a radio transmission that could
shut out any radio transmitters (JAMMING
function activated in control unit).
X
SUPERVIS.TX xxx
INPUT DESCR.
Radio input xxx has transmitted a per-
son-detected communication.
TAMP.MOD.IN xx
MODULE DESCR.
The tamper of the inputs expansion mod-
ule on the bus xx has been tampered with.
Check module tamper.
X
TAMP.MOD.OUT xx
MODULE DESCR.
The tamper of the exits expansion module
on the bus xx has been tampered with.
Check module tamper.
X
TAMP.MOD.RX xx
MODULE DESCR.
The tamper of the radio receiver of bus xx
has been tampered with. Check module
tamper.
X
TAMP.TASTIERA xx
KEYPAD DESCR.
The xx keypad’s opening tamper has been
tampered with. Check keypad tamper.
X
OUTPUT M.TECN
Exiting the technical menu is logged in the
events log.
BATT. BREAK. xx RES.BATTERY xx
CONT. UNIT
PWR.DESCR.
Main battery breakdown. X
LOCAL CONN.
The communication between control unit
and PC (uploading - downloading program-
ming and events) is logged in the events log.
xx NETWORK BREAK.
NETWORK BACK xx
CONT. UNIT
PWR.DESCR.
No 230 Vac power supply breakdown. X
AUTO TEST
The autotest is normally used to check
whether the control unit is up and running
via a telephone notification.
X
CODE N. xxx
CODE DESCR.
Entering a code (user or technician’s) is
logged in the events log.
X
KEY N. xxx
KEY DESCR.
The action of approaching keys to insert-
ers is logged in the events log.
X
SYS.BREAKDOWN
R.SYS.BREAKDOWN
Generic system breakdown notification. The
breakdown can be caused by the batteries, the
230 network, the power supply unit, or fuses).
X
SYS.TEC.ALA.
RES.TEC.ALA.1
Generic technical alarm event. It is gener-
ated with an area technical alarm (if it is not
associated to an area’s technical input, the
system technical alarm is not generated).
X
GEN.SYS.ALA.
RES.GEN.ALA.1
The generic general alarm event is gener-
ated with either an area alarm or a system
tamper alarm.
X X
PWR BRK.DN. xx
CONT. UNIT
PWR.DESCR.
Control unit power supply – fuses break-
down notification.
X
POWER-ON
The event is logged when the control unit
is powered up for the first time or it is reset
(the re-start button is pressed on the con-
trol unit’s board).