Page 17 - Programming Manual 24805480/14-11-2012 319F92C ver. 1.2 -The data and information in this manual may be changed at any time with no obligation on BRAHMS’s part to notify anyone of this.
ENGLISH
2.8 Outputs
OUTPUTS 12
*
CHANGE OUTP 001
OUTPUT 01
TYPE 001
STABLE
Status: (Default:
STABLE
)
S
A
STABLE
the output’s activity follows the status of the associated event.
Example: the output is activated by the OPEN condition of the associated
input.
IMPULSIVE
the output’s activity is determined by the associated event but
only for a certain time, the duration of which is selectable.
*
Parameter viewable only if the output is an impulsive one.
Activation duration: (Default:
000
)
S
A
Duration time of the impulsive output activation.
Example: opening a door lock via code. An impulsive output is associated to a code, with a 3-second
activation time.
IMPULSE TIME 001
[0..255] SEC 000
Duration time activation
Parameters viewable only if the output is a stable one.
Activation delay: (Default:
000
)
S
A
Delayed time between the activation command and the output’s activation.
Deactivation delay: (Default:
000
)
S
A
Delayed time between the deactivation command and the output’s deactivation.
Example: check whether the system is on or off through an input. In the output Association menu,
assign the switching on status of the areas to one stable programmed output and with zero second
delay on activation and deactivation times.
ARM DELAY 001
[0..255] SEC 000
Del. Eng.
Del. Dis.
STATUS
OUTPUT
COMMAND
OUTPUT
DISARM DELAY 001
[0..255] SEC 000