Page 33 - Programming Manual 24805480/14-11-2012 319F92C ver. 1.2 -The data and information in this manual may be changed at any time with no obligation on BRAHMS’s part to notify anyone of this.
ENGLISH
Default parameters:
F
S
A
Press
*
to execute the default parameters.
The default parameters do not erase the codes and keys you purchased.
Control unit version:
F
S
A
To know the model and version of the control unit in use
2.20 Default parameters
2.21 Control unit version
DEFAULT 26
PARAMETERS
CONTROL UNIT 27
VERSION
*
*
DEFAULT PARAM.?
*=YES #=ESC
VERSION
PROXINET8 1.0.X
3 Events messaging
The events are composed by:
• TIMEandDATE
• EVENTDESCRIPTION(activation/restoring)
• EVENTINDEX
• EVENTDESCRIPTION(part2)
ACTIVATION RESTORE DESCRIPTION 2 CAUSE
Telephone notifications group
Alarm
Sabotage
Technical
Burglary
Switching on
Out of order
Code
Key
Input
Various
SWITCHING ON
TOTAL
Areas switched-on:
We have a switching on event when there
are only switching on actions (total or par-
tial). If switching on all of the areas man-
aged by the control unit, the second de-
scription will read TOTAL, whereas partial
switching on will indicated the switched
on areas (example ##--#).
X
PARTIALIS.
Areas switched-on:
The partialisation even takes place when
we have non-total area switching o actions
(partial switching o). The second descrip-
tion will show the switched on or of status
of the remaining areas (example ##--#).
X
SWITCHING OFF
The switching o event takes place when
the system is totally switched o.
X
ALA. TAMPER xx RES. TAMPER xx
CONT. UNIT
PWR.DESCR.
Control unit or auxiliary power supply unit
opening or ripping tampering detected
Check tamper integrity.
X
ALA.INP.TAMP. xxx
RES.INP.TAMP. xxx
INPUT DESCR.
Input xxx has been tampered with (either
cut or short-circuited depending on its bal-
ancing), check continuity along the input’s
electrical line. If it has restored (by itself)
anyhow check the input’s electric line be-
cause there may some faulty connections.
X
AREA ALARM xx
RES. AREA ALARM xx
AREA DESCR.
When an input is in alarm state the associ-
ated areas will be too.
X
INP. ALARM.xxx
RESTORE INPUT xxx
INPUT DESCR.
Input xxx is in alarm (in unbalanced state). X
BATTERY TX xxx
INPUT DESCR.
Radio input xxx battery is run down. Re-
place asap.
X