Page 36 - Programming Manual 24805480/14-11-2012 319F92C ver. 1.2 -The data and information in this manual may be changed at any time with no obligation on BRAHMS’s part to notify anyone of this.
ENGLISH
4 Reference laws
5 Declaration
Declares under its own responsibility that the following products for security alarm units:
PROXINET8
… comply with essential requisites and dispositions, given by the following Directives and applicable Regulations listed below.
--- DIRECTIVES---
2006/95/CE Low VoLTagE DIRECTIVE
2004/108/CE ELECTRomagnETIC CompaTIbILITy DIRECTIVE
1999/05/EC DIRECTIVE on RaDIo EquIpmEnT anD TELECommunICaTIonS TERmInaL EquIpmEnT anD muTuaL aCknowLEDgEmEnT of ThEIR CompLIanCE To STanDaRDS.
En 50130-4 + a1 + a2 aLaRm SySTEmS.
paRT 4: ELECTRomagnETIC CompaTIbILITy.
En 60950-1 InfoRmaTIon - SECuRITy TEChnoLogy EquIpmEnT.
paRT 1: gEnERaL REquIREmEnTS.
En 61000-6-3 ELECTRomagnETIC CompaTIbILITy (EmC).
paRT 6-3: gEnERaL STanDaRDS - EmISSIon STanDaRD foR RESIDEnTIaL, CommERCIaL anD LIghT InDuSTRy zonES.
ETSI ES 203 021-1 TERmInaL EquIpmEnT (TE); aTTaChmEnT REquIREmEnTS foR pan-EuRopEan appRoVaL foR ConnECTIon To ThE anaLoguE pubLIC SwITChED TELEphonE nETwoRkS (pSTnS) of TE (ExCLuDIng TE SuppoRTIng ThE VoICE TELEphony SERVICE) In
whICh nETwoRk aDDRESSIng, If pRoVIDED, IS by mEanS of DuaL TonE muLTI fREquEnCy (DTmf) SIgnaLLIng.
En 300 220-3 ELECTRomagnETIC CompaTIbILITy anD RaDIo SpECTRum maTTERS (ERm); ShoRT RangE DEVICES (SRD); RaDIo EquIpmEnT To bE uSED In ThE 25 mhz To 1 000 mhz fREquEnCy RangE wITh powER LEVELS RangIng up To 500 mw;
paRT 3: haRmonIzED En CoVERIng ESSEnTIaL REquIREmEnTS unDER aRTICLE 3.2 of ThE R&TTE DIRECTIVE.
En 301 489-3 ELECTRomagnETIC CompaTIbILITy anD RaDIo SpECTRum maTTERS (ERm); ELECTRomagnETIC CompaTIbILITy (EmC) STanDaRD foR RaDIo EquIpmEnT anD SERVICES;
paRT 3: SpECIfIC ConDITIonS foR ShoRT-RangE DEVICES (SRD) opERaTIng on fREquEnCIES bETwEEn 9 khz anD 40 ghz.
En 50130-5 aLaRm SySTEmS
paRT 5: EnVIRonmEnTaL TEST mEThoDS.
En 50131-1 aLaRmS SySTEmS - InTRuSIon anD buRgLaRy aLaRm SySTEmS.
gEnERaL REquIREmEnTS.
En 50131-6 aLaRmS SySTEmS - InTRuSIon anD buRgLaRy aLaRm SySTEmS.
paRT 6: powER SuppLIERS.
CompLIES wITh ThE pRoDuCT STanDaRD CEI 79-2 SEConD LEVEL.
BPT S.p.a a Socio Unico
Head and Registered Oce
Via Cornia, 1/b – 33079 – Sesto al Reghena (PN) - Italy
http://www.bpt.it – mailto:info@bpt.it
Below are the standards to bring the system up to code with standard EN 50131:
- The inserter buzzer notifications cannot be deactivated (EN50131-1 8.3.8.2);
- The "24H" and "Technological" inputs must not be used;
- The inputs configured as "Switch on" are compliant only if controlled from devices whose number of combinations exceeds 10000;
- If the system incorporates devices that report breakdowns, these must be connected to the breakdown input;
- The telephone combiner must be active;
- The system must contain an self-powered external siren to signal any intrusion alarms;
- The number of alarms for input auto-exclude must be set between 3 and 10;
- Power supply failure notification time must be set at one minute (1 min);
- Do not activate quick switching on;
- The "Stop Communication" option must not be activated when control unit is switched off;
- Input time 1 and 2 must be set to a maximum of 45 sec. (EN50131-1 8.3.8.2);
- The battery test time must be set above 5 minutes;
- Activate SEE SYSTEM STATUS setting at ≤ than xx seconds;