BilgMon488 Instruction Manual vAD 28(38)
BRANNSTROM SWEDEN AB
www.brannstrom.se
14 LOG ENTRIES
Power was turned on at given date
and time (yymmdd hh:mm:ss).
Separator signal input turned from
not activated to activated.
Separator signal input turned from
activated to not activated.
Measured oil content went from
below set valve ppm level to above (in
example valve setting is 15 ppm).
Automatic stopping device activated.
Measured oil content went from
above set valve ppm level to below (in
example valve setting is 15 ppm).
Automatic stopping device
deactivated.
PPM average when below set valve
ppm limit since latest SEP ON signal or
latest PPM BELOW event.
Valve ppm level setting was
changed to indicated value (in
example to 5 ppm).
Simulation was turned on.
Simulation was turned off.
Time offset was adjusted (in settings
menu). Offset to BilgMon builtin
realtime clock in hours, minutes and
seconds is shown.
BilgMon builtin realtime clock was set
(logged once at factory).
A new sensor was attached.
Log: POWER ON
060102 11:36:32
Log: POWER OFF
060102 14:06:10
Log: SEP ON
060102 12:10:12
Log: SEP OFF
060102 12:23:34
Log: PPM > 15
060102 12:15:13
Log: PPM < 15
060102 12:17:42
Log: PPM AVG 04
051021 09:47:29
Log: PPM SET 05
060102 13:10:07
Log: SIM_ON
060102 12:09:50
Log: SIM_OFF
060102 12:24:19
Log: TIME OFFSET
+0:59:46
Log: RTC SET
051021 09:47:29
Log: NEW SENSOR
051021 12:47:29