67XXU USB/Serial Scale Service Manual 57
6.2 Geographical Adjustment
1. When GEO is selected, press the [TARE] key to enter Geographical
Adjustment.
2. When CODE is displayed, press the [UNIT] key to select geographical position
code or input user local gravity value directly.
3. When CODE is selected, choose the position code of the scale being used
(00-70) according to the elevation and latitude from Table 6.1 by using the
[HOLD] and [UNIT] keys.
4. Press [TARE] key to confirm.
CAUTION! Only an authorized manufacturer representative or certified
verification personnel may make these changes. Changing the Geographical
setting alters the calibration values!