67XXU USB/Serial Scale Service Manual 63
Table 7.2 Bit Definition of H
1
H
2
H
3
H
4
7.6 Commands and Response
7.6.1 Parameter NCI-SCP01
Set the USER-COM-LYOUT parameter to SCP01.
W
1
---W
6
Reading data, 1-6 bytes (six digits)
<DP> Decimal point
U
1
U
2
U
3
U
4
U
5
Measure units, kg, lb, lb:oz, % or pcs; 2-5 bytes
<Add> Address of scale; 2 bytes (00-99)
<Prompt> Prompt characters of output content; max. 11bytes
Bit
Byte 1 (H
1
) Byte 2 (H
2
) Byte 3 (H
3
) Byte 4 (H
4
)
0 0 = stable 0 = not under capacity 00 = compare disable
01 = lower limit
10 = ok
11= upper limit
00 = normal weighing
01 = count weighing
10 = percent weighing
11 = other mode
1 = not stable 1 = under capacity
1 0 = not at zero point 0 = not over capacity
1 = at zero point 1 = over capacity
2 0 = RAM ok 0 = ROM ok 0 = gross weight 0 = not in HOLD
1 = RAM error 1 = ROM error 1 = net weight 1 = in HOLD
3 0 = eeprom OK 0 = calibration ok 0 = initial zero ok 0 = battery ok
1 = eeprom error 1 =calibration error 1 = initial zero error 1 = low battery
4 always 1 always 1 always 1 always 1
5 always 1 always 1 always 1 always 1
6 always 0 always 1 always 1 always 0
7 parity Parity parity Parity