EasyManua.ls Logo

Brecknell 6702U - Page 64

Brecknell 6702U
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64 67XXU USB/Serial Scale Service Manual
Command: W<CR> (57h 0dh), request current reading
Command: S<CR> (53h 0dh), request current status
Command: Z<CR> (5ah 0dh)
If ZERO function cannot be activated, it will return to current scale status.
Command: T<CR> (54h 0dh)
If TARE function cannot be activated, it will return to current scale status.
Response
<LF>^^^^^^^^U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---over capacity
<LF>_ _ _ _ _ _ _ _ U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---under capacity
<LF> - - - - - - - - U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---zero-point error
Note: U
1
U
2
U
3
U
4
U
5
is 1,2,3 or 5 bytes according to current unit: kg, lb, pcs, g, oz, lb:oz
<LF><P>W
1
W
2
W
3
W
4
W
5
<DP>W
6
U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---normal data
Note: (1) The decimal point position is determined by CONFG-PRIM.D
(2) If current unit is "lb:oz", the format will be similar with following:
<LF><P>W
1
W
2
W
3
lb<SP>W
4
W
5
<DP>W
6
oz<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>
Response
<LF> H
1
H
2
H
3
H
4
<CR><ETX>
Response
Zero function is activated (simulate ZERO key) and it returns to current scale status.
<LF> H
1
H
2
H
3
H
4
<CR><ETX>
Response
TARE function is activated (simulate TARE key), and then returns scale status.
<LF> H
1
H
2
H
3
H
4
<CR><ETX>

Table of Contents

Related product manuals