OPERATING CONDITIONS
Operating temperature: -10° to + 55°C (14° to 131°F)
Storage temperature: -20° to + 85°C (-4° to 158°F)
Relative humidity: 95 %
CE MARKING
The R-DPA96 A/AN A40/A41 complies with :
• The requirements of the European directive on electromagnetic compatibility (EMC) no. 89/336/CEE dated 3 May 1989,
modied by directive no. 92/31/CEE dated 28 April 1992 and by directive no. 93/68/CEE dated 22 July 1993.
• Low voltage directive no. 73/23/CEE dated 19 February 1973, modied by directive no. 93/68/CEE dated 22 July 1993.
ELECTROMAGNETIC COMPATIBILITY
Immunity to electrostatic discharges: IEC 61000-4-2 - Level III
Immunity to radiated radio-frequency elds: IEC 61000-4-3 - Level III
Immunity to electrical fast transients/bursts: IEC 61000-4-4 - Level IV
Immunity to impulse waves: IEC 61000-4-5 - Level IV
Immunity to conducted disturbances: IEC 61000-4-6 - Level III
Immunity to power frequency magnetic elds: IEC 61000-4-8 - Level IV
Conducted and radiated emissions: IEC 61000-6-4 - Class B
Immunity to voltage dips and short interruptions: IEC 61000-4-11
CLIMATE
Operating-temperature range: IEC 60068-2-1/IEC 60068-2-2
-10 °C to +55 °C
Storage temperature range: IEC 60068-2-1/IEC 60068-2-2
-20 °C to +85 °C
Humidity: IEC 60068-2-30 - 95 %
Saling fog: IEC 60068-2-52 - 2,5 % NaCl
MECHANICAL CHARACTERISTICS
Vibration from 10 to 50 Hz: IEC 60068-2-6 - 2 g
INSULATION
Installation category: III (480VAC ph/ph)
Degree of pollution: 2
Rated impulse withstand voltage: IEC 60947-1 - V imp: 4 kV
Front face: Classe II
Electric security: IEC 61010-1
CERTIFICATION
UL 61010-1 N° le : E257746
TECHNICAL CHARACTERISTICS