EasyManua.ls Logo

Broaster 1600 - 7 - ROTARY DIAL SOLID STATE CONTROL PANEL; CONTROLLER PROGRAMMING

Broaster 1600
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTROLLER PROGRAMMING
CAUTION: Check oil level before
turning cook/filter switch to COOK.
Action: Turn cook/filter switch to
COOK.
Response: Display alternates
between number values for cook tem-
perature, cook time and LO (idle
mode). LO will disappear when oil
temperature has reached cook temper-
ature value.
Action: Press one of three buttons
once.
Response: Display reads pro-
grammed value of button pressed.
Display will return to idle mode after
five seconds.
Temperature:
Action: Press cook temperature but-
ton twice within one second.
Response: Programming mode has
been entered. Flashing display reads
“###F.” (### = temperature value ie:
360°F)
Action: If desired, turn rotary knob to
change displayed value. Press cook
temperature button to enter new value
into memory.
Response: Controller returns to idle
mode.
Time:
Action: Press cook time button twice
within one second.
Response: Programming mode has
been entered. Flashing display reads
“##:##.” (##:## = time value ie: 08:00)
Action: If desired, turn rotary knob to
change displayed value in fifteen sec-
ond increments. Press cook time but-
ton to enter new value into memory.
Response: Controller returns to idle
mode.
AUTO COMP (Automatic Time Compen-
sation):
Action: Press AUTO COMP button
twice within one second.
Response: Programming mode has
been entered. Flashing display reads
ON or OFF.
Action: If desired, turn rotary knob to
change displayed value. Press AUTO
COMP button to enter new value into
memory.
Response: Controller returns to idle
mode.
7 - 2
Manual #13897 10/97