SOLID STATE CONTROLLER TIPS
COMPLAINT CAUSE REMEDY
Display reads FAIL
1. There is a controller fail-
ure
1. Turn cook/filter switch
OFF. Contact service
person.
Display reads HI
1. Oil temperature too high 1. Turn cook/filter switch
OFF. Contact service
person.
Display reads PROB
1. There is a temperature
sensor probe failure
1. Turn cook/filter switch
OFF. Contact service
person.
Display reads CHEC
1. Gas valve not ON
(1800GH)
2. Pilot light out (1800GH)
3. Open or faulty wall fuse
4. Oil temperature not rising
properly
1. Turn ON
2. Light pilot
3. Check wall fuse or circuit
breaker
4. Turn cook/filter switch
OFF. Contact service
person.
14 - 2
Manual #13897 10/97