14 - TROUBLESHOOTING
All adjustments and repairs shall be made by an authorized Broaster Company representative.
ELECTRICAL TIPS
COMPLAINT CAUSE REMEDY
POWER ON light not illumi-
nated
1. Main power OFF
2. Cook/filter switch OFF
3. Hi-limit tripped (1800E
and 1600 solid state)
4. Unplugged
1. Turn ON
2. Turn to COOK
3. Turn cook/filter switch
OFF. Contact service
person.
4. Plug in
Timer will not time
1. Main power OFF
2. Cook/filter switch OFF
3. Solid state controller in
program mode
4. Pressure regulating valve
OPEN
1. Turn ON
2. Turn to COOK
3. Exit program mode
4. CLOSE
HEAT ON light not illumi-
nated
1. Main power OFF
2. Cook/filter switch OFF
3. Solid state controller in
program mode
4. Oil temperature has
reached programmed
temperature
5. Temperature control OFF
(1600)
1. Turn ON
2. Turn to COOK
3. Exit program mode
4. Unit ready to cook in
5. Turn temperature control
ON. Temperature control
may not be cycling on and
off (1600).
14 - 1
Manual #13897 10/97